Key publications
- Gronenschild E. High-precision On-Line Quantitative Cardiovascular Analysis with CAAS II. Poster presentation, 5th symposium for coronary angiography, June 1993, Rotterdam …………………………………………………….. …………………………………………………………………………...
- Haase J, Escaned J, Montauban van Swijndregt E, Ozaki Y, Gronenschild E, Slager CJ, Serruys PW. Experimental Validation of Geometric and Densitometric Coronary Measurements on the New Generation Cardiovascular Angiography Analysis System (CAASII). Catheterization and Cardiovascular Diagnosis 1993; 30: 104-114 …………………………………………….
- Gronenschild E, Janssen J, Tijdens F. CAAS II: A Second Generation system for Off-Line and On-Line Quantitative Coronary Angiography. Catheterization and Cardiovascular Diagnosis 1994; 33: 61-75 ……………………………………………………………………………..
- Hausleiter J, Jost S, Nolte CWT, Dirschinger J, Kastrati A, Stiel GM, Wunderlich W, Fischer F, Linderer T, Hausmann D and Schömig A. Comparative in-vitro validation of eight first- and second-generation quantitative coronary angiography systems. Coronary Artery Disease; 1997; 8(2) …………………………………………………….
- Haase J, Slager CJ, Keane D, Foley DP, den Boer A, Doriot PA, Serruys PW. Quantification of intracoronary Volume by Videodensitometry: Validation Study Using Fluid Filling of Human Coronary Casts, Catheterization and Cardiovascular Diagnosis 1994; 33: 89-94 …………………………………………………………………………………………………………..
- Girasis C, van Geuns RJ, Onuma Y, Serruys PW. Essentials of quantitative angiography for bifurcated Lesions. EuroIntervention 2010; 6: J36-J43 …………………………………………………………….
- Garrone P, Biodi-Zoccai G, Salvetti I, Sina N, Sheinab I, Stella P, and Agostoni P. Quantitative Coronary Angiography in the Current Era: Principles and Applications. Journal of Interventional Cardiology 2009, 22: 527-536 ……………………………………………………………
- Foley DP, Escaned J, Strauss BH, di Mario C, Haase J, Keane D, Hermans WRM, Rensing BJ, de Feyter PJ, and Serruys PW. Quantitative Coronary Angiography (QCA) in Interventional Cardiology: Clinical Application of QCA Measurements. Progress in Cardiovascular Diseases 1994; 36(5): 363-384 ………………………………………………………………
- Seissl H, Peukert K, Geiger B, Verstraelen B. QCA Impact of Imaging Parameters to Accuracy and Precision. International Sessions for the Japanese Circulation Society 1996 ……………………………………………………………………………………………………
- Strauss et al., Technologic considerations and practical limitations in the use of quantitative angiography during percutaneous coronary recanalization (use and methodology). Progress in Cardiovascular diseases 1994; 36(5): 343-362 ………………………………………………………………………………………
- Serruys PW, Booman F, Troost GJ, Reiber JHC, Gerbrands JJ, van den Brand M, Cherrier F, Hugenholtz PG. Computerized quantitative coronary angiography applied to percutaneous transluminal coronary angioplasty: advantages and limitations. Transluminal Coronary Angioplasty and Intracoronary Thrombolysis. Kaltenbach A, Grüntzig K, Rentrop W, Bussman D (Eds). Springer-Verlag Berlin, 1982: 110-124 !!Een witte regel zodat er een extra enter ontstaat!!
- Zijlstra F, Ommeren J van, Reiber JHC, Serruys PW. Does the quantitative assessment of coronary artery dimensions predict the physiologic significance of a coronary stenosis? Circulation 1987; 75: 1154-1161 …………………………………………………………………………………………
- Serruys PW, Reiber JHC, Wijns W, van den Brand M, Kooijman CJ, ten Katen HJ, Hugenholtz PG. Assessment of percutaneous transluminal coronary angioplasty by quantitative coronary angiography: diameter versus densitometric area measurements. American Journal of Cardiologie 1984; 54: 482-488 ………………………………………………………………………………….
- Serruys PW, Foley DP, de Feyter PJ. Quantitative Coronary Angiography in Clinical Practice. Developments in Cardiovascular Medicine Vol.145, Kluwer Academic Publishers, Dordrecht/Boston/London 1994
Database
Authors | Title | Journal | Year | Type |
|---|---|---|---|---|
| Kang HJ, Oh IY, Chung JW Yang HM, Suh JW, Park KW, Kwon TK, Lee HY, Cho YS, Youn TJ, Koo BK, Kang WY, Kim W, Rha SW, Bae JH, Chae IH, Hoi DJ and Kim HS | Effects of Celecoxib On Restenosis after Coronary Intervention and Evolution of Atherosclerosis (Mini-COREA) Trial: celecoxib, a double-edged sword for patients with angina | European Heart Journal | 2012 | article |
| Cremers B, Milewski K, Clever YP, Aboodi MS, Biedermann M, Thim T, Kelsch B, Kaluza GL, Scheller B, Granada JF | Long-term effects on vascular healing of bare metal stents delivered via paclitaxel-coated balloons in the porcine model of restenosis | Catherization and Cardiovascualar Interventions | 2012 | article |
| Nagai T, Hirano T, Tsunoda M, Hosaka H, Kishino Y, Katayama T, Matsumura K, Miyagawa T, Kohsaka S and Anzai T | Left circumflex coronary artery is protected against no-reflow phenomenon following percutaneous coronary intervention for coronary artery disease | Heart and vessels | 2012 | article |
| Kim JS, Hong MK, Ko YG, Choi D, Yoon JH, Choi SH, Hahn JY, Gwon HC, Jeong MH, Kim HS, Seong IW, Yang JY, Rha SW, Tahk SJ, Seung KB, Park SJ, Jang Y | Impact of intravascular ultrasound guidance on long-term clinical outcomes in patients treated with drug-eluting stent for bifurcation lesions: data from a Korean multicenter bifurcation registry | Am. Heart J. | 2011 | article |
| Kang SJ, Mintz GS, Kim WJ, Lee JY, Park DW, Yun SC, Lee SW, Kim YH, Lee CW, Han KH, Kim JJ, Park SW, Park SJ | Effect of intravascular ultrasound findings on long-term repeat revascularization in patients undergoing drug-eluting stent implantation for severe unprotected left main bifurcation narrowing | Am. J. Cardiol. | 2011 | article |
| Chen SL, Santoso T, Zhang JJ, Ye F, Xu YW, Fu Q, Kan J, Paiboon C, Zhou Y, Ding SQ, Kwan TW | A Randomized Clinical Study Comparing Double Kissing Crush With Provisional Stenting for Treatment of Coronary Bifurcation Lesions Results From the DKCRUSH-II (Double Kissing Crush versus Provisional Stenting Technique for Treatment of Coronary Bifurcation Lesions) Trial. | J Am Coll Cardiol | 2011 | article |
| Wiemer M, König A, Rieber J, Sohn HY, Leibig M, Theisen K, Klauss V, Langer C, Lindner O, Horstkotte D, Schiele TM | Sirolimus-eluting stent implantation versus beta-irradiation for the treatment of in-stent restenotic lesions: clinical and ultrasound results from a randomised trial | EuroIntervention | 2011 | article |
| Kang SJ, Mintz GS, Park DW, Lee SW, Kim YH, Whan Lee C, Han KH, Kim JJ, Park SW, Park SJ | Mechanisms of In-Stent Restenosis After Drug-Eluting Stent Implantation: Intravascular Ultrasound Analysis | Circ Cardiovasc Interv | 2011 | article |
| Amoroso G, van Geuns RJ, Spaulding C, Manzo-Silberman S, Hauptmann KE, Spaargaren R, García-García HM, Serruys PW and Verheye S | Amoroso G, van Geuns RJ, Spaulding C, Manzo-Silberman S, Hauptmann KE, Spaargaren R, García-García HM, Serruys PW, Verheye S | EuroIntervention | 2011 | article |
| Muhammad KI, Lombardi WL, Christofferson R and Whitlow PL | Subintimal guidewire tracking during successful percutaneous therapy for chronic coronary total occlusions: Insights from an intravascular ultrasound analysis. | Catheter Cardiovasc Interv | 2011 | article |
| Chen SL, Xu T, Zhang JJ, Ye F, Hu ZY, Tian NL, Zhang YJ, Kotani JI and Zhang JX | Angioscopy study from a large patient population comparing sirolimus-eluting stent with biodegradable versus durable polymer. | Catheter Cardiovasc Interv | 2011 | article |
| Kyono H, Kozuma K, Shiratori Y, Maeno Y, Lino R, Takada K, Ishikawa S, Konno K, Yamamoto H and Suzuki N | Angiographic and clinical outcomes of 100 consecutive severe calcified lesions requiring rotational atherectomy prior to sirolimus-eluting stent implantation in hemodialysis and non-hemodialysis patients. | Cardiovascular Intervention and Therapeutics | 2011 | |
| Jong-Young Lee, Duk-Woo Park, Young-Hak Kim, Sung-Cheol Yun, Won-Jang Kim, Soo-Jin Kang, Seung-Whan Lee, Cheol-Whan Lee, Seong-Wook Park, and Seung-Jung Park | Incidence, Predictors, Treatment, and Long-Term Prognosis of Patients With Restenosis After Drug-Eluting Stent Implantation for Unprotected Left Main Coronary Artery Disease | J Am Coll Cardiol | 2011 | article |
| Miyai N, KinoshitaN, Oota K, Yamada T, Nakamura R, Irie H, Hashimoto T, Tamaki S and Matsubara H | Long-term angiographic outcomes of post-Sirolimus-eluting stent restenosis in Japanese patients | Heart and Vessels | 2011 | article |
| Brunel P, Martin G, Bressollette E, Leurent B, Banus Y | "Inverted" provisional T stenting, a new technique for Medina 0,0,1 coronary bifurcation lesions: feasibility and follow-up | EuroIntervention | 2010 | article |
| Park KW, Kim CH, Lee HY, Kang HJ, Koo BK, Oh BH, Park YB and Kim HS | Does "late catch-up" exist in drug-eluting stents: insights from a serial quantitative coronary angiography analysis of sirolimus versus paclitaxel-eluting stents | Am. Heart J. | 2010 | article |
| Kim JS, Kim JS, Kim, TH, Fan C Lee JM, Kim W, Ko YG, Choi D, Hong MK and Jang Y | Comparison of neointimal coverage of sirolimus-eluting stents and paclitaxel-eluting stents using optical coherence tomography at 9 months after implantation | Circ. J. | 2010 | article |
| LØland KH, Bleie O, Blix AJ, Strand E, Ueland PM, Refsum H, Ebbing M, Nordrehaug JE and Nygard O | Effect of homocysteine-lowering B vitamin treatment on angiographic progression of coronary artery disease: a western norway B vitamin intervention trial (WENBIT) substudy | Am. J. Cardiol. | 2010 | article |
| Wood F, Banarjee S and Brilakis E | Analysis of saphenous vein graft lesion composition using near-infrared spectroscopy and intravascular ultrasonography with virtual histology | Atherosclerosis | 2010 | article |
| Kedhi E, Joesoef KS, McFadden E, Wassing J, Van Mieghem C, Goedhart D and Smits PC | Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice (COMPARE): a randomised trial | Lancet | 2010 | article |
| Pesarini G, Amoruso A, Ferrero V, Bardelli C, Fresu LG, Perobelli L, Scappini P, De Luca G, Brunelleschi S, Vassanelli C and Ribichini F | Cytokines release inhibition from activated monocytes, and reduction of in-stent neointimal growth in humans | Atherosclerosis | 2010 | article |
| Sarno G, Garg S, Van der Giessen W and Serruys PW | Intravascular ultrasound radiofrequency analysis after optimal coronary stenting with initial quantitative coronary angiograpphy guidance | EuroIntervention | 2010 | article |
| Wykrzykowska JJ, Arbab-Zadeh A, Godoy G, Miller JM, Lin S, Vavere A, Paul N, Niinuma H, Hoe J, Brinker J, Khosa F, Sarwar S, Lima J and Clouse ME | Assessment of in-stent restenosis using 64-MDCT: analysis of the CORE-64 Multicenter International Trial | AJR Am J Roentgenol | 2010 | article |
| Groothuis JG, Kremers FP, Beek AM, Brinckman SL, Tuinenburg AC, Jerosch-Herold M, Van Rossum AC and Hofman MB | Comparison of dual to single contrast bolus magnetic resonance myocardial perfusion imaging for detection of significant coronary artery disease | J Magn Reson Imaging | 2010 | article |
| Kyono H, Bezerra HG and Costa MA | Optical coherence tomography (OCT) strut-level analysis of drug-eluting stents (DES) in human coronary bifurcations | Eurointervention | 2010 | article |
| Dewey M, Vavere AL, Arbab-Zadeh A, Miller JM, Sara L, Cox C, Cottlieb I, Yoshioka K, Paul N, Hoe J, De Roos A, Lardo AC, Lima JA and Clouse ME | Patient characteristics as predictors of image quality and diagnostic accuracy of MDCT compared with conventional coronary angiography for detecting coronary artery stenoses: CORE-64 Multicenter International Trial | AJR Am J Roentgenol | 2010 | article |
| Schellings D, Dambrink J, Hoorntje J, De Boer M, Van 't Hof A and Suryapranata H | Long-term comparison of balloon angioplasty with provisional stenting versus routine stenting in patients with non-ST-elevation acute coronary syndrome | Netherlands Heart Journal | 2010 | article |
| Chen SL, Chen JP, Mintz G, Xu B, Kan J, Ye F, Zhang J, Sun X, Xu Y, Jiang Q, Zhang A and Stone GW | Comparison between the NERS (New Risk Stratification) score and the SYNTAX (Synergy between Percutaneous Coronary Intervention with Taxus and Cardiac Surgery) score in outcome prediction for unprotected left main stenting | JACC Cardiovasc Interv | 2010 | article |
| Park SJ, Kim KH, Oh IY, Shin DH, Park KI, Seo MK, Chung JW, Park KW, Lee HY, Kang HJ, Koo BK, Youn TJ and Kim HS | Comparison of Plain Balloon and Cutting Balloon Angioplasty for the Treatment of Restenosis With Drug-Eluting Stents vs Bare Metal Stents | Circ J | 2010 | article |
| Chen SL, Xu B, Mintz G, Ye F, Zhang JJ, Kan J, Sun XW, Zhang AP, Chen JG, Qian J and Kwan TW | Clinical outcome after management of unprotected left main in-stent restenosis after bare metal or drug-eluting stents | Chin. Med. J. | 2010 | article |
| Stojkovic S, Ostojic M, Nedeljkovic M, Stankovic G, Beleslin B, Vukcevic V, Orlic D, Arandjelovic A, Kostic J, Dikic M and Tomasevic M | Systemic rapamycin without loading dose for restenosis prevention after coronary bare metal stent implantation | Catheter Cardiovasc Interv | 2010 | article |
| Onuma Y, Tanimoto S, Veldhof S and Serruys PW | Efficacy of Everolimus Eluting Stent Implantation in Patients with Calcified Coronary Culprit Lesions: 2-year angiographic and 3-year clinical results from the SPIRIT II study | Catherization and Cardiovascular Interventions | 2010 | article |
| Ozaki Y, Okumura M, Ismail TF, Naruse H, Hattori K, Kan S, Ishikawa M, Kawai T, Takagi Y, Ishii J, Prati F and Serruys PW | The fate of incomplete stent apposition with drug-eluting stents: an optical coherence tomography-based natural history study | Eur Heart J | 2010 | article |
| Eshtehardi P, Meier B and Windecker S | Impact of arterial injury on neointimal hyperplasia after implantation of drug-eluting stents in coronary arteries: an intravascular ultrasound study | EuroIntervention | 2010 | article |
| Serruys PW, Garg S, Toyloy S, Fitzgerald P | A randomised comparison of novolimus-eluting and zotarolimus-eluting coronary stents: 9-month follow-up results of the EXCELLA II study | Eurointervention | 2010 | article |
| Wiemer M, Degenhardt R, Vallbracht C, Horstkotte D, Schneider H, Nienaber C, Bocksch W, Boxberger M and Unverdorben M | The paclitaxel-eluting coroflex stent study II (PECOPS II) acute and 6-month clinical and angiographic follow-up, 1-year clinical follow-up | J Interv Cardiol | 2010 | article |
| Meijs MF, De Vries JJ, Rutten A, Budde RP, De Vos AM, Meijboom WB, Cramer MJ, De Feyter PJ, Doevendans PA and Prokop M | Does slice thickness affect diagnostic performance of 64-slice CT coronary angiography in stable and unstable angina patients with a positive calcium score? | Acta Radiol | 2010 | article |
| Komura N, Hibi K, Kusama I, Otsuka F, Mitsuhashi T, Endo M, Iwahashi N, Okuda J, Tsukahara K, Kosuge M, Ebina T, Umemura S and Kimura K | Plaque location in the left anterior descending coronary artery and tissue characteristics in angina pectoris: an integrated backscatter intravascular ultrasound study | Circ. J. | 2010 | article |
| Merkle N, Wohrle J, Nusser T, Grebe O, Spiess J, Torzewski J and Hombach V | Diagnostic performance of magnetic resonance first pass perfusion imaging is equally potent in female compared to male patients with coronary artery disease | Clin Res Cardiol | 2010 | article |
| Serruys PW, Silber S, Garg S, Van Geuns RJ, Richardt G, Buszman PE, Kelbæk H, Van Boven AJ, Hofma SH, Linke A, Klauss V, Wijns W, Macaya C, Garot P, Dimario C, Manoharan G, Kornowski R, Ischinger T, Bartorelli A, Ronden J, Bressers M, Gobbens P, Negoita M, Van Leeuwen F and Windecker S | Comparison of Zotarolimus-Eluting and Everolimus-Eluting Coronary Stents | N Engl J Med | 2010 | article |
| Reifart N, Hauptmann K, Rabe A, Enayat D and Giokoglu K | Short and long term comparison (24 months) of an alternative sirolimus-coated stent with bioabsorable polymer and bare metal stent of similar design in cronic total occlusions: the CORACTO trial | EuroIntervention | 2010 | article |
| Undas A, Zalewski J, Krochin M, Siudak Z, Sadowski M, Pregowski J, Dudek D, Janion M, Witkowski A and Zmudka K | Altered plasma fibrin clot properties are associated with in-stent thrombosis | Arterioscler. Thromb. Vasc. Biol. | 2010 | article |
| Jahnke C, Gebker R, Manka R, Schnackenburg B, Fleck E and Paetsch I | Navigator-gated 3D blood oxygen level-dependent CMR at 3.0-T for detection of stress-induced myocardial ischemic reactions | JACC Cardiovasc Imaging | 2010 | article |
| Lee CW, Kang SJ, Park DW, Lee SH, Kim YH, Kim JJ, Park SW, Mintz GS and Park SJ | Intravascular ultrasound findings in patients with very late stent thrombosis after either drug-eluting or bare-metal stent implantation | J. Am. Coll. Cardiol. | 2010 | article |
| Cortese B, Micheli A, Picchi A, Coppolaro A, Bandinelli L, Severi S and Limbruno U | Paclitaxel-coated balloon versus drug-eluting stent during PCI of small coronary vessels, a prospective randomised clinical trial. The PICCOLETO study | Heart | 2010 | article |
| Rinker A, Nusser T, Grossmann G, Koenig W and Wohrle J | Angiographic results of a Tacrolimus-eluting stent in acute coronary syndrome lesions | Clin Res Cardiol | 2009 | article |
| Serruys PW, Ormiston JA, Onuma Y, Regar E, Gonzalo N, Garcia-Garcia HM, Nieman K, Bruining N, Dorange C, Miquel-Hebert K, Veldhof S, Webster M, Thuesen L and Dudek D | A bioabsorbable everolimus-eluting coronary stent system (ABSORB): 2-year outcomes and results from multiple imaging methods | Lancet | 2009 | article |
| Cremers B, Biedermann M, Mahnkopf D, Bohm M and Scheller B | Comparison of two different paclitaxel-coated balloon catheters in the porcine coronary restenosis model | Clin Res Cardiol | 2009 | article |
| Opolski MP, Pracon R, Mintz GS, Okabe T, Pregowski J, Lee SY, Van der Waal EC, Kalinczuk L, Roy P, Smith KA, Torguson R, Xue Z, Satler LF, Kent KM, Pichard AD, Waksman R and Weissman NJ | Relation of drug-eluting stent strut distribution to stent thrombosis in coronary arteries | Am. J. Cardiol. | 2009 | article |
| Y. Han, Jing Q, Xu B, Yang L, Liu H, Huang G, Tresukusol D, Wang S et al. | Safety and efficacy of biodegradable polymer-coated sirolimus-eluting stents in "real-world" practice: 18-month clinical and 9-month angiographic outcomes | JACC Cardiovasc Interv | 2009 | article |
| Brodoefel H, Burgstahler C, Tsiflikar I, Reimann A, Schroeder S, Claussen CD, Heuschmid M and Kopp AF | Dual-source CT: effect of heart rate, heart rate variability, and calcification on image quality and diagnostic accuracy. | Radiology | 2008 | article |
| Hakim DE, Garot P, Champagne S, Lesault PF and Teiger E | Impact of bifurcation lesions on clinical outcome and prognosis of primary angioplasty in acute myocardial infarction | EuroIntervention | 2008 | article |
| Miller JM, Rochitte CE, Dewey M, Arbab-Zadeh A, Niinuma H, Gottlieb I, Paul N, Clouse ME, Shapiro EP, Hoe J, Lardo AC, Bush DE, De Roos A, Cox C, Brinker J and Lima JA | Diagnostic performance of coronary angiography by 64-row CT | N. Engl. J. Med. | 2008 | article |
| Drieghe B, Madaric J, Sarno G, Manoharan G, Bartunek J, Heyndrickx GR, Pijls NHJ and De Bruyne B | Assessment of renal artery stenosis: side-by-side comparison of angiography and duplex ultrasound with pressure gradient measurements. | Eur Heart J | 2008 | article |
| Valgimigli M, Campo G, Percoco G, Bolognese L, Vassanelli C, Colangelo S, De Cesare N, Rodriguez AE, Ferrario M, Moreno P, Piva T, Sheiban I, Pasquetto G, Prati F, Nazzaro MS, Parrinello G and Ferrari R | Comparison of angioplasty with infusion of tirofiban or abciximab and with implantation of sirolimus-eluting or uncoated stents for acute myocardial infarction: the MULTISTRATEGY randomized trial. | JAMA | 2008 | article |
| Budoff M, Dowe D, Jollis J, Scherer M, Bellinger R, Martin A, Benton R, Delano A and Min J | Diagnostic Performance of 64-Multidetector Row Coronary Computed Tomographic Angiography for Evaluation of Coronary Artery Stenosis in Individuals Without Known Coronary Artery Disease | Journal of American College of Cardiology | 2008 | article |
| Johnson TRC, Nikolaou K, Becker A, Leber AW, Rist C, Wintersperger BJ, Reiser MF, Becker CR | Dual-source CT for chest pain assessment. | Eur Radiol | 2008 | article |
| BrenerSJ, Ivanc TB and Hu T | The relation between extent of coronary artery disease measured by quantitative coronary angiography and changes in lipid profile: insights from trials of atherosclerosis regression. | J Invasive Cardiol | 2008 | article |
| Pocock SJ, Lansky AJ, Mehran R, Popma JJ, Fahy MP, Na Y, Dangas G, Moses JW, Pucelikova T, Kandzari DE, Ellis SG, Leon MB and Stone G | Angiographic surrogate end points in drug-eluting stent trials: a systematic evaluation based on individual patient data from 11 randomized, controlled trials. | J Am Coll Cardiol | 2008 | article |
| Ghostine S and Paul JF | Non-invasive diagnosis of ischaemic heart failure using 64-slice computed tomography. | Eur Heart J | 2008 | article |
| Dani S, Kukreja N, Shah B and Dutta JP | Biodegradable-polymer-based, sirolimus-eluting Supralimus® stent: 6-month angiographic and 30 month clinical follow-up results from the Series I prospective study | EuroIntervention | 2008 | article |
| Wellenius G, Mukamal K, Kulshreshtha A, Asonganyi S and Mittleman M | Depressive Symptoms and the Risk of Atherosclerotic Progression Among Patients With Coronary Artery Bypass Grafts | Circulation | 2008 | article |
| Stella P, Mueller R, De Bruyne B, Hauptmann K, Maurice MC, Chevalier B, Fajadet J, Sievert H and Grube E | One year results of a new in situ length-adjustable stent platform with a biodegradable Biolimus A9 eluting polymer: results of the CUSTOM-II trial | EuroIntervention | 2008 | article |
| Nixdorff U, Kufner C, Achenback S, Stilliniakis N, Voigt J, Flachskampf F, Daniel W and Ropers D | Head-to-head comparison of dobutamine stress echocardiography and cardiac CT for the detection of significant coronary artery disease. | Cardiology | 2008 | article |
| Costa MA, Angiolillo DJ, Tannenbaum M, Driesman M, Chu A, Patterson J, Kuehl W, Battaglia J, Dabbons S, Shamoon F, Flieshman B, Niederman A and Bass TA | Impact of stent deployment procedural factors on long-term effectiveness and safety of sirolimus-eluting stents (final results of the multicenter prospective STLLR trial). | Am J Cardiol | 2008 | article |
| Cademartiri F, Maffei E, Palumbo AA, Malago R, Grutta LL, Meiijboon WB, Aldrovandi A, Fusaro M, Vignali L, Menozzi A, Brambilla V, Coruzzi P, Midiri M, Kirchin MA, Mollet NRA and Krestin GP | Influence of intra-coronary enhancement on diagnostic accuracy with 64-slice CT coronary angiography. | Eur Radiol | 2008 | article |
| Glineur D, D'Hoore W, El Khoury G, Sondji S, Porcelet A, Astarci P, Verhelst R, Noirhomme P and Hanet C | Angiographic Predictors of 6-Month Patency of Bypass Grafts Implanted to the Right Coronary Artery | JACC | 2008 | article |
| Pugliese F, Mollet N, Hunnink M, Cademartiri P, Van Mieghem C, Nieman K, Meijboom W, Van Domburg R, Weustink A, Dijkshoorn M, De Feyter P and Krestin G | Diagnostic Performance of Coronary CT Angiography by Using Different Generations of Multisection Scanners: Single-Center Experience1 | Radiology | 2008 | article |
| Chun EJ and Park JH | Effects of Nitroglycerin on the Diagnostic Accuracy of Electrocardiogram-gated Coronary Computed Tomography Angiography. | J Comput Assist Tomogr | 2008 | article |
| Von Ziegler F and Knez A | Detection of significant coronary artery stenosis with 64-slice computed tomography in heart transplant recipients: a comparative study with conventional coronary angiography. | Int J Cardiovasc Imaging | 2008 | article |
| Mollet NR, Cademartiri F, Van Mieghem C, Meijboom B, Pugliese F, Runza G, Baks T, Dikkeboer J, McFadden EP, Freericks MP, Kerker JP, Zoet SK, Boersma E, Krestin GP and De Feyter PJ | Adjunctive value of CT coronary angiography in the diagnostic work-up of patients with typical angina pectoris. | Eur Heart J | 2007 | article |
| Melikian N, Kearney MT, Thomas MR, De Bruyne B, Shah AM and MacCarthy PA | A simple thermodilution technique to assess coronary endothelium-dependent microvascular function in humans: validation and comparison with coronary flow reserve. | Eur Heart J | 2007 | article |
| Menichelli M, Parma A, Pucci E, Fiorilli R, De Felice F, Nazzaro M, Giulivi A, Alborino D, Azzellino A and Violini R | Randomized trial of Sirolimus-Eluting Stent Versus Bare-Metal Stent in Acute Myocardial Infarction (SESAMI). | J Am Coll Cardiol | 2007 | article |
| Prati F | The RESTART project: high dose atorvastatin helps control RESTenosis AfterR sT enting procedures at high risk for restenosis. Results from a prospective study and matched control group comparison | EuroIntervention | 2007 | article |
| Pontone G, Andreini D, Ballerini G, Nobili E and Pepi M | Diagnostic work-up of unselected patients with suspected coronary artery disease: complementary role of multidetector computed tomography, symptoms and electrocardiogram stress test. | Coron Artery Dis | 2007 | article |
| Watkins MW, Hesse B, Green CE, Greenberg NL, Manning M, Chaudhry E, Dauerman HL and Garcia MJ | Detection of coronary artery stenosis using 40-channel computed tomography with multi-segment reconstruction. | Am J Cardiol | 2007 | article |
| Andreini D, Pontone G, Pepi M, Ballerini G, Bartorelli AL, Magini A, Quaglia C, Nobili E and Agostoni P | Diagnostic accuracy of multidetector computed tomography coronary angiography in patients with dilated cardiomyopathy. | J Am Coll Cardiol | 2007 | article |
| Jim MH, Chow WH and Ho HH | Stenting of unprotected distal left main coronary artery bifurcation stenoses using modified crush technique with double kissing balloon inflation (sleeve technique): immediate procedure result and early clinical outcome. | J Interv Cardiol | 2007 | article |
| Chevalier B | Randomised comparison of Noburi(TM), biolimus A9-eluting coronary stent with a Taxus(R), paclitaxel-eluting coronary stent in patients with stenosis in native coronary arteries: the Nobori 1 Trial. | EuroIntervention | 2007 | article |
| Costa MA, Shoemaker S, Futamatsu H, Klassen C, Angiolillo DJ, Nguyen M, Siuciak A, Gilmore P, Zenni MM, Guzman L, Bass TA and Wilke N | Quantitative magnetic resonance perfusion imaging detects anatomic and physiologic coronary artery disease as measured by coronary angiography and fractional flow reserve. | J Am Coll Cardiol | 2007 | article |
| Togni M, Eber S, Widmer J, Billinger M, Wenaweser P, Cook S, Vogel R, Seiler C, Eberli FR, Maier W, Corti R, Roffi M, Luscher TF, Garachemani A, Hess OM, Wandel S, Meier B, Juni P an d Windecker S | Impact of vessel size on outcome after implantation of sirolimus-eluting and paclitaxel-eluting stents: a subgroup analysis of the SIRTAX trial. | J Am Coll Cardiol | 2007 | article |
| Costa MA, Sabate M, Angiolillo DJ, Hu P, Jimenez-Quevedo P, Corros C, Alfonso F, Hernandez-Antolin R, Macaya C and Bass TA | Relocation of minimal luminal diameter after bare metal and drug-eluting stent implantation: incidence and impact on angiographic late loss. | Catheter Cardiovasc Interv | 2007 | article |
| Onuma Y, Müller R, Ramcharitar S, Van Geuns RJ, Louvard Y, Morel MA, Morice MC, Davis R, Kaplan AV, Lefèvre T, Grube E and Serruys PW. | Tryton I, First-In-Man (FIM) study: six month clinical and angiographic outcome, analysis with new quantitative coronary angiography dedicated for bifurcation lesions | Eurointervention | 2007 | article |
| Kuiper KKJ, Salem M, Rotevatn S, Mills J and Nordrehaug JE | Implementing a best-treatment strategy with intracoronary brachytherapy for in-stent restenosis in patients at high risk for recurrence. | Cardiovasc Revasc Med | 2007 | article |
| Okabe T, Mintz GS, Buch AN, Roy P, Hong YJ, Smith KA, Torguson R, Gevorkian N, Xue Z, Satler LF Kent KM, Pichard AD, Weissman NJ and Waksman R | Intravascular ultrasound parameters associated with stent thrombosis after drug-eluting stent deployment. | Am J Cardiol | 2007 | article |
| Park TH, Tayan N, Takeda K, Jeon HK, Quinones MA and Zoghbi WA | Supine bicycle echocardiography improved diagnostic accuracy and physiologic assessment of coronary artery disease with the incorporation of intermediate stages of exercise. | J Am Coll Cardiol | 2007 | article |
| Inoue T | Mobilization of CD34-positive bone marrow-derived cells after coronary stent implantation | Circulation | 2007 | article |
| Schepis T, Koepfli P, Leschka S, Desbiolles L, Husmann L, Gaemperli O, Eberli FR, Wildermuth S, Marincek B, Luscher TF, Alkadhi H and Kaufmann PA | Coronary artery stent geometry and in-stent contrast attenuation with 64-slice computed tomography. | Eur Radiol | 2007 | article |
| Meijboom WB, Van Mieghem CAG, Mollet NR, Pugliese F, Weustink AC, Van Pelt N, Cademartiri F, Nieman K, Boersma E, De Jaegere P, Kerstin GP and De Feyter PJ | 64-slice computed tomography coronary angiography in patients with high, intermediate, or low pretest probability of significant coronary artery disease. | J Am Coll Cardiol | 2007 | article |
| Hassan W, Al-Sergani J, Buraiki JA, Dunn B, Turki FA, Akhras N, Elshaer F, Nawaz M, Kharabsheh S and ElKum N | Immediate and intermediate results of intracoronary stand-alone bolus administration of eptifibatide during coronary intervention (ICE) study. | Am Heart J | 2007 | article |
| Tsuchida K. and Van der Giessen W | In vivo validation of a novel three-dimensional quantitative coronary angiograpohy system (CardiOp-B): comparison with a convententional two-dimensional system (CAASII) and with special reference to OCT | EuroIntervention | 2007 | article |
| Fort S, Kornowski R, Silber S, Lewis B, Bildodeau L, Almagor Y, Van Remortel E, Morice MC and Colombo A | ''''Fused-Gold'''' vs. ''''Bare'''' stainless steel NIRflex stents of the same geometric design in diseased native coronary arteries. Long-term results from the NIR TOP study. | EuroIntervention | 2007 | journal |
| Cook S, Wenaweser P, Togni M, Billinger M, Morger C, Seiler C, Vogel R, Hess O, Meier B and Windecker S | Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation. | Circulation | 2007 | article |
| Flammer AJ, Hermann F, Sudano I, Spieker L, Hermann M, Cooper KA, Serafini M, Luscher TF, Ruschitzka F, Noll G and Corti R | Dark chocolate improves coronary vasomotion and reduces platelet reactivity. | Circulation | 2007 | article |
| Malagutti P, Nieman K, Meijboom WB, Van Mieghem CAG, Pugliese F, Cademartiri F, Mollet NR, Boersma E, De Jaegere PP and De Feyter PJ | Use of 64-slice CT in symptomatic patients after coronary bypass surgery: evaluation of grafts and coronary arteries. | Eur Heart J | 2007 | article |
| Weustink AC, Meijboom WB, Mollet NR, Otsuka M, Pugliese F, Van Mieghem C, Malago R, Van Pelt N, Dijkshoorn ML, Cademartiri F, Krestin GP and De Feyter PM | Reliable high-speed coronary computed tomography in symptomatic patients. | J Am Coll Cardiol | 2007 | article |
| De Feyter P and Van Mieghem C | Detection and characterization of coronary bifurcation lesions with 64-slice computed tomography coronary angiography. | Eur Heart J | 2007 | article |
| Zhang Q, Xu B, Yang YJ, Zhang RY, Li JP, Qiau SB, Zhang JS, Hu J, Qin XW, Hong T, Chen JL, Huo Y, Shen WF and Gao RL | Sirolimus-eluting cobalt alloyed stents in treating patients with coronary artery disease: six-month angiographic and one-year clinical follow-up result. A prospective, historically controlled, multi-center clinical study. | Chin Med J (Engl) | 2007 | article |
| E. Iofina | Advantage of sirolimus-eluting stents compared to intracoronary radiation therapy 30 months after treatment of in-stent restenosis | EuroIntervention | 2007 | article |
| Adriano M Caixeta et al. | Enhanced inflammatory response to coronary stenting marks the development of clinically relevant restenosis. | Catheter Cardiovasc Interv | 2007 | article |
| Ai-Hsien Li et al. | More coronary artery stenosis, more cerebral artery stenosis? A simultaneous angiographic study discloses their strong correlation. | Heart Vessels | 2007 | article |
| B. K. Koo et al. | Effect of celecoxib on restenosis after coronary angioplasty with a Taxus stent (COREA-TAXUS trial): an open-label randomised controlled study | Lancet | 2007 | article |
| J Wohrle et al. | Comparison of the slow-release polymer-based paclitaxel-eluting Taxus-Express stent with the bare-metal Express stent for saphenous vein graft interventions. | Clin Res Cardiol | 2007 | article |
| Heleen M M Beusekom et al. | Drug-eluting stents show delayed healing: paclitaxel more pronounced than sirolimus. | Eur Heart J | 2007 | article |
| J S Wijpkema et al. | Discordance between anatomical and functional coronary stenosis severity. | Neth Heart J | 2007 | article |
| Hai-bo Liu et al. | A comparison of clinical and angiographic outcomes after Excel bioabsorbable polymer versus Firebird durable polymer rapamycin-eluting stent for the treatment of coronary artery disease in a | Chin Med J (Engl) | 2007 | article |
| HW Pyun et al. | Concomitant multiple revascularizations in supra-aortic arteries: Short-term results in 50 patients | American Journal of Neuroradiology | 2007 | article |
| K. Dawkins A. Colombo | The European cobalt stent with antiproliferative for restenosis trial (EuroSTAR): 12 month results | EuroIntervention | 2007 | article |
| Carvalho et al | Small coronary arteries treated with sirolimus-eluting stents: one-year results of the PORTO multicentre registry | EuroIntervention | 2007 | journal |
| T. Misztalski-Jamka et al. | Diagnosis of ischaemic heart disease by myocardial contrast echocardiography during supine bicycle stress. | Kardiol Pol | 2006 | article |
| B. Scheller et al. | Treatment of coronary in-stent restenosis with a paclitaxel-coated balloon catheter | N. Engl. J. Med. | 2006 | article |
| Carlos A G Van Mieghem et al. | Multislice spiral computed tomography for the evaluation of stent patency after left main coronary artery stenting: a comparison with conventional coronary angiography and intravascular ultrasound. | Circulation | 2006 | article |
| Mario J Garcia et al. | Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis. | JAMA | 2006 | article |
| Speck | Neointima inhibition: comparison of effectiveness of non-stent-based local drug delivery and a DES in porcine coronary arteries. | Radiology | 2006 | article |
| D. Ropers et al. | Diagnostic accuracy of noninvasive coronary angiography in patients after bypass surgery using 64-slice spiral computed tomography with 330-ms gantry rotation. | Circulation | 2006 | article |
| N. Werner | Circulating CD31+/Annexin V+ apoptotic microparticles correlate with coronary endothelial function in patients with coronary artery disease. Atherosclerosis, Thrombosis and Vascular Biology | -- | 2006 | article |
| Radke | A double blind, randomized, placebo controlled multicenter clinical trial to evaluate the effects of angiotensinII receptor blocker candesartam cilexetil on intimal hyperplasia after coronary stent implantation. | American Heart Journal | 2006 | article |
| H Kang | Differential effect of intracoronary infusion of mobilized peripheral blood stem cells by granulocyte colony-stimulating factor on LV function and remodeling in patients with acute myocardial infarction vs old myocardial infarction. | Circulation | 2006 | article |
| Sjoerd H Hofma et al. | Indication of long-term endothelial dysfunction after sirolimus-eluting stent implantation. | Eur Heart J | 2006 | article |
| Johannes Rieber et al. | Cardiac magnetic resonance perfusion imaging for the functional assessment of coronary artery disease: a comparison with coronary angiography and fractional flow reserve. | Eur Heart J | 2006 | article |
| A. E. Rodriguez et al. | Oral rapamycin after coronary bare-metal stent implantation to prevent restenosis: the Prospective, Randomized Oral Rapamycin in Argentina (ORAR II) Study. | J Am Coll Cardiol | 2006 | article |
| A. E. Rodriguez et al. | Oral rapamycin after coronary bare-metal stent implantation to prevent restenosis: the Prospective, Randomized Oral Rapamycin in Argentina (ORAR II) Study. | J Am Coll Cardiol | 2006 | article |
| S. Windecker et al. | Sirolimus-eluting and paclitaxel-eluting stents for coronary revascularization | N. Engl. J. Med. | 2005 | article |
| Willem J. Giessen et al. | Assessment of stent dimensions with a novel intracoronary balloon-based system: comparative study versus intravascular ultrasound and quantitative coronary angiography. The CAMUS - Coronary Angioplasty Metricath vs. UltraSound Trial | EuroIntervention | 2005 | article |
| Selvanayagam Jerosch-Herold | Resting Myocardial blood flow is impaired in hibernating myocardium. | Circulation | 2005 | article |
| Hoye et al. | Percutanoues Therapy of Bifurcation Lesions with Drug Eluting Stent Implantation: The Culotte Technique Revisited. | Intern Journ of Cardiov Interventions | 2005 | article |
| Bernard Bertrand et al. | Comparison of synchrotron radiation angiography with conventional angiography for the diagnosis of in-stent restenosis after percutaneous transluminal coronary angioplasty. | Eur Heart J | 2005 | article |
| G. S. Mintz et al. | Intravascular ultrasound assessment of neointima distribution and the length of stent that was free of intravascular ultrasound-detectable intimal hyperplasia in paclitaxel-eluting stents. | Am J Cardiol | 2005 | article |
| Tsuchida M | Revisiting late loss and neointimal volumetric measurements in a drug-eluting steng trial. Analysis from the SPIRIT FIRST trial. | Cath and Cardiov Interv | 2005 | article |
| T Palmerini | Preprocedural levels of C-reactive protein and leukocyte counts predict 9-month mortality adter coronary angioplasty for the treatment of unprotected left main coronary artery stenosis. | Circulation | 2005 | article |
| C. C. Cock et al. | Major dissection of the coronary sinus and its tributaries during lead implantation for biventricular stimulation: angiographic follow-up. | Europace | 2004 | article |
| G Werner | Prevention of Lesion Recurrence in Chronic Total Coronary Occlusions by Paclitaxel-Eluting Stents. | ournal of the American College of Cardiology | 2004 | article |
| P Lemos | Comparison of late luminal loss response pattern after sirolimus-eluting stent implantation or conventional stenting. | Circulation | 2004 | article |
| B Scheller | Paclitaxel balloon coating, a novel method for prevention and therapy of restenosis. Circulation | 110 | 2004 | article |
| G. S. Werner et al. | Sirolimus-eluting stents for the prevention of restenosis in a worst-case scenario of diffuse and recurrent in-stent restenosis. | Catheter Cardiovasc Interv | 2004 | article |
| Lemos | Clinical, angiographic, and procedural predictors of angiographic restenosis in complex patients: an evaluation from the Rapamycin-Eluting Stent Evaluated At Rotterdam Cardiology Hospital (RESEARCH) study | Circulation | 2004 | article |
| M. Sanmartin et al. | Validation of 4 French catheters for quantitative coronary analysis: in vivo variability assessment using 6 French guiding catheters as reference scaling devices | J Invasive Cardiol | 2004 | article |
| S. J. Park et al. | A paclitaxel-eluting stent for the prevention of coronary restenosis | N. Engl. J. Med. | 2003 | article |
| K Kozuma | Sensitivity and specificity of QCA in detecting coronary arterial remodelling after intracoronary brachytherapy: a comparison to serial volumetric three-dimensional intravascular ultrasound analysis. Can we detect positive remodelling by luminography? | J Invasive Cadiol. | 2003 | article |
| F. F. Willems et al. | Coronary endothelial function in hyperhomocysteinemia: improvement after treatment with folic acid and cobalamin in patients with coronary artery disease. | J Am Coll Cardiol | 2002 | article |
| R. J. Peters et al. | Videodensitometric quantitative angiography after coronary balloon angioplasty, compared to edge-detection quantitative angiography and intracoronary ultrasound imaging. | Eur Heart J | 2000 | article |
| F. Alfonso | Videodensitometric vs edge-detection quantitative angiography. Insights from intravascular ultrasound imaging. | Eur Heart J. | 2000 | article |
| E. Gronenschild | Correction for geometric image distortion in the x-ray imaging chain: local technique versus global technique. | Med Phys | 1999 | article |
| J. H. Reiber et al. | The effect of DICOM on QCA and clinical trials | Int J Card Imaging | 1998 | article |
| E. Gronenschild | The accuracy and reproducibility of a global method to correct for geometric image distortion in the x-ray imaging chain. | Med Phys | 1997 | article |
| J. Hausleiter et al. | Comparative in-vitro validation of eight first- and second-generation quantitative coronary angiography systems. | Coron Artery Dis | 1997 | article |
| H. Seissl et al. | Quantitative coronary angiography: impact of imaging parameters on accuracy and confidence interval. | Heart Vessels | 1997 | article |
| M. J. Wolters-Geldof et al. | Clinical methods to determine coronary flow and myocardial perfusion. | Int J Card Imaging | 1997 | article |
| B. Reimers et al. | New approach to quantitative angiographic assessment after stent implantation. | Cathet Cardiovasc Diagn | 1997 | article |
| G. Koning et al. | Effect of lossy data compression on quantitative coronary measurements. | Int J Card Imaging | 1997 | article |
| M Sonka et al. | Adaptive approach to accurate analysis of small-diameter vessels in cineangiograms. | IEEE Trans Med Imaging | 1997 | article |
| V. Legrand et al. | Variability in estimation of coronary dimensions from 6F and 8F catheters. | Cathet Cardiovasc Diagn | 1996 | article |
| J. Escaned et al. | Significance of automated stenosis detection during quantitative angiography. Insights gained from intracoronary ultrasound imaging. | Circulation | 1996 | article |
| P. A. Sirnes et al. | Reproducibility of quantitative coronary analysis, Assessment of variability due to frame selection, different observers, and different cinefilmless laboratories. | Int J Card Imaging | 1996 | article |
| Kirkeeide RL. Wunderlich W | Analytic isocenter calibration. A new approach for accurate x-ray gantries. | Angiology | 1995 | article |
| D. Keane et al. | Comparative validation of quantitative coronary angiography systems. Results and implications from a multicenter study using a standardized approach. | Circulation | 1995 | article |
| M. Sonka et al. | Robust simultaneous detection of coronary borders in complex images. | IEEE transactions on medical imaging | 1995 | article |
| D. Keane et al. | In vivo validation of an experimental adaptive quantitative coronary angiography algorithm to circumvent overestimation of small luminal diameters. | Cathet Cardiovasc Diagn | 1995 | article |
| M Lang et al. | Improving the applicability of myocardial densitometry and parametric imaging by extended automated densogram analysis. | Int J Card Imaging | 1995 | article |
| Buis B. Broek JG | Three-dimensional densitometric reconstruction and visualization of stenosed coronary artery segments. | Comput Med Imaging Graph. | 1995 | article |
| P.M.J. J.H. Reiber | Overestimation of small vessel sizes by QCA. | Catheter Cardiovasc Diagn | 1995 | article |
| Ozaki et al. | Acute Clinical and Angiographic Results With the New AVE Micro Coronary Stent in Bailout Management | The American Journal of Cardiology | 1995 | article |
| Y Ozaki et al. | Coronary arteriography for quantitative analysis: experimental and clinical comparison of cinefilm and video recordings. | Am Heart J | 1995 | article |
| J H Reiber et al. | Catheter sizes for quantitative coronary arteriography. | Cathet Cardiovasc Diagn | 1994 | article |
| F Ribichini et al. | On-line quantitative coronary analysis in clinical practice: one step closer to reality? | Cathet Cardiovasc Diagn | 1994 | article |
| J Haase et al. | Quantification of intracoronary volume by videodensitometry: validation study using fluid filling of human coronary casts. | Cathet Cardiovasc Diagn | 1994 | article |
| J. Haase | Percutaneous implantation of coronary stenosis phantoms in an anesthetized swine model to validate current quantitative angiographic analysis systems, in Progress in quantitative coronary arteriography | -- | 1994 | article |
| E Gronenschild et al. | CAAS. II: A second generation system for off-line and on-line quantitative coronary angiography. | Cathet Cardiovasc Diagn | 1994 | article |
| J R Herrman et al. | Radiological quality of coronary guiding catheters: a quantitative analysis. | Cathet Cardiovasc Diagn | 1994 | article |
| J. Haase | How reliable are geometric coronary measurements? In vitro and in vivo validation of digital and cinefilm-based quantitative coronary analysis systems, in Quantitative Coronary Angiography in Clinical Practice | Kluwer Academic Publishers | 1994 | article |
| H. Suryapranata S. PW | Application of quantitative coronary angiography in the study of pharmacologically induced coronary vasomotion. | Quantitative coronary angiography in clinical practice | 1994 | article |
| D P Foley et al. | Quantitative coronary angiography (QCA) in interventional cardiology: clinical application of QCA measurements. | Prog Cardiovasc Dis | 1994 | article |
| B H Strauss et al. | Technologic considerations and practical limitations in the use of quantitative angiography during percutaneous coronary recanalization. | Prog Cardiovasc Dis | 1994 | article |
| M Sonka et al. | Lumen centerline detection in complex coronary angiograms. | IEEE Trans Biomed Eng | 1994 | article |
| M. Sonka | Simultanous detection of both coronary borders. | IEEE transactions on medical imaging | 1993 | article |
| B. H. Strauss | he use of quantitative coronary angiography (QCA) in interventional cardiology | Advances in Quantitative Coronary Arteriography | 1993 | article |
| A Uehata et al. | Accuracy of electronic digital calipers compared with quantitative angiography in measuring coronary arterial diameter. | Circulation | 1993 | article |
| G. M. Stiel | AWOS: angiographic workstation for digital quantitative coronary angiography. | IEEE Trans Biomed Eng | 1993 | article |
| J Haase et al. | Experimental validation of geometric and densitometric coronary measurements on the new generation Cardiovascular Angiography Analysis System (CAAS II). | Cathet Cardiovasc Diagn | 1993 | article |
| J H Reiber et al. | Accuracy and precision of quantitative digital coronary arteriography: observer-, short-, and medium-term variabilities. | Cathet Cardiovasc Diagn | 1993 | article |
| E. Gronenschild | Effect of spatial orientation on the image-intensifiesr distortion in quantitative coronary angiography. | Computers in Cardiology | 1993 | article |
| J Escaned et al. | Quantitative angiography during coronary angioplasty with a single angiographic view: a comparison of automated edge detection and videodensitometric techniques. | Am Heart J | 1993 | article |
| N Danchin et al. | Visual versus quantitative assessment of the severity of coronary artery stenoses: can the angiographers eye be reeducated? | Am Heart J | 1993 | article |
| J Haase et al. | In-vivo validation of on-line and off-line geometric coronary measurements using insertion of stenosis phantoms in porcine coronary arteries. | Cathet Cardiovasc Diagn | 1992 | article |
| R. Kirkeeide R. JH | Comparison of angiogram calibration methods: an American-European experience | -- | 1992 | article |
| J Lesperance D Waters | Measuring progression and regression of coronary atherosclerosis in clinical trials: problems and progress. | Int J Card Imaging | 1992 | article |
| J. Beier et al. | Edge detection for coronary angiograms: Error correction and impact of derivates | IEEE Trans Biomed Eng | 1992 | article |
| T. Linderer et al. | Edge detection in quantitative coronary arteriography (QCA): The impact of image zoom on edge positioning, accuracy, precision and discrimination | Dpt. of Cardiology | 1992 | article |
| R. Kirkeeide | Coronary obstructions, morphology and physiologic significance. | Quantitative coronary arteriography | 1991 | article |
| D F Fortin et al. | Pitfalls in the determination of absolute dimensions using angiographic catheters as calibration devices in quantitative angiography. | Am J Cardiol | 1991 | article |
| A. V. Bruschke et al. | uidelines Coronary Arteriography | Neth. J. Cardiol | 1991 | article |
| W H Leung et al. | Evaluation of catheters and metallic catheter markers as calibration standard for measurement of coronary dimension. | Cathet Cardiovasc Diagn | 1990 | article |
| H Marinus et al. | Pulsatile coronary flow determination by digital angiography. | Int J Card Imaging | 1990 | article |
| A V Bruschke et al. | Arteriographic evaluation of small coronary arteries. | J Am Coll Cardiol | 1990 | article |
| P M Zwet et al. | A new approach for the automated definition of path lines in digitized coronary angiograms. | Int J Card Imaging | 1990 | article |
| T Sugahara et al. | Automatic detection method of stenotic lesions in coronary cineangiograms. | Int J Card Imaging | 1989 | article |
| S Jost et al. | Clinical application of quantitative coronary angiography using the CAAS system: preliminary results of the INTACT study (International Nifedipine Trial on Antiatherosclerotic Therapy). | Int J Card Imaging | 1988 | article |
| J H Reiber et al. | Assessment of short-, medium-, and long-term variations in arterial dimensions from computer-assisted quantitation of coronary cineangiograms. | Circulation | 1985 | article |
| W Wijns et al. | Quantitative angiography of the left anterior descending coronary artery: correlations with pressure gradient and results of exercise thallium scintigraphy. | Circulation | 1985 | article |
| R A Vogel | The radiographic assessment of coronary blood flow parameters. | Circulation | 1985 | article |
| Reiber | Computer assisted analysis of the severity of obstructions from coronary cineangiograms: a methodological review. | Automedica | 1984 | article |
| J. H. Reiber | Coronary artery dimensions from cineangiograms-Methodology and validation of a computer-assisted analysis procedure | IEEE Trans Biomed Eng | 1984 | article |
| C. J. Kooijman | Computer-aided quantitation of the severity of coronary obstructions from single view cineangiograms | IEEE Trans Biomed Eng | 1982 | article |
| R A Kruger | Estimation of the diameter of and iodine concentration within blood vessels using digital radiography devices. | Med Phys | 1981 | article |
| W G Austen et al. | A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. | Circulation | 1975 | article |