CAAS QCA / QVA 3D

Key publications

  • Girasis C, Schuurbiers JCH, Marumatsu T, Aben JP, Onuma Y, Soekhradj S, Morel MA, Van Geuns RJ, Wentzel JJ and Serruys PW. Advanced three-dimensional quantitative coronary angiographic assessment of bifurcation lesions: methodology and phantom validation. EuroIntervention 2013; 8: 1451-1460

     

  • Schuurbiers JCH, Lopez NG, Ligthart J, Gijsen, FJH, Dijkstra J, Serruys PW, van der Steen AF and Wentzel JJ. In vivo validation of CAAS QCA-3D coronary reconstruction using fusion of angiography and intravascular ultrasound (ANGUS). Catheter Cardiovasc Interv 2009; 73(5): 620-6


  • Bruining N, Tanimoto S, Otsuka M, Weustink A, Ligthart J, Van Mieghem C, De Feyter PJ, Van Domburg R and Serruys, PW. Quantitative multi-modality imaging analysis of a bioabsorbable poly-L-lactid acid stent design in the acute phase: a comparison between 2 and 3D-QCA, QCU and QMSCT-CA. EuroIntervention 2009; 4(15): 285-291

  • Ramcharitar S, Daemen J, Patterson M, Van Geuns RJ, Boersma E, Serruys PW and Van der Giessen W. First direct in vivo comparison of two commercially available three-dimensional quantitative coronary angiography systems. Catherization and Cardiovascular Interventions 2009; 71: 44-50 

  • Rzeszutko LJ, Partyka L, Roman LW, Tijdens F, Barycz G, Slots T, Nyssen V, Kaluza G and Dariusz D. Accuracy and precision of a novel 3D angiographic reconstruction and quantification software (CAAS QCA 3D) in measuring intracoronary length using marker wire in angioplasty patients. TCT 2007


  • Onuma Y, Girasis C, Aben JP, Sarno G, Piazza N, Lokkerbol C, Morel MA, Serruys PW. A novel dedicated 3-dimensional quantitative coronary analysis methodology for bifurcation lesions. Eurointervention 2011. Epub ahead of print

 

Database

Authors
Title
Journal
Year
Type
Foin N, Sen S, Petraco R, Nijjer S, Torii R, Kousera C, Broyd C, Mehta V, Xu Y, Mayet J, Hughes A, Di Mario C, Krams R, Francis D, Davies JMethod for Percutaneously Introducing, and Removing, Anatomical Stenosis of Predetermined Severity In Vivo: "The Stenotic Stent"J of Cardiovasc. Trans. Res2013article
Girasis C, Schuurbiers JCH, Muramatsu T, Aben JP, Onuma Y, Soekhradj S, Morel MA, Van Geuns RJ, Wentzel JJ, Serruys PWAdvanced three-dimensional quantitative lesions: methodology and phantom validationEuroIntervention2013article
Magro M, Girasis C, Bartorelli AL, Tarantini G, Russo F, Trabattoni D, D'Amico GD, Galli M, Gómez Jaume A, De Sousa Almeida M, Simsek C, Foley D, Sonck J, Lesiak M, Kayaert P, Serruys PW, Van Geuns RJAcute procudural and six-month clinical outcome in patients treated with a dedicated bifurcation stent for left main stem disease: the TRYTON LM multicentre registry EuroIntervention2013article
Chen SI, Kan J, Zhang JJ, Hu ZY, Xu T Hemodynamic change in wall shear stress in patients with coronary bifurcation lesions treated by double kissing crush or single-stent techniqueChinese Medical Journal2012article
Chen SI, Teguh S, Zhang JJ, Ye F, Xu YW, Fu Q, Kan J, Chitprapai P, Zhou Y, Ding SQ, Tak W KCoronary bifurcation angle from 3-D predicts clinical outcomes after stenting bifurcation lesionsChinese Medical Journal2012article
Legutko J, Rzeszutko L, Partyka L, Depukat R, Wojdyla M, Barycz G, Wizimirski M, Stefaniak J, Tijdens F, Bary L, Dubiel J, Dudek D,
Grzegorz L. Kaluza4
Comparison of three-dimensional and two-dimensional
quantitative coronary analysis measuring intracoronary
lengths in patients undergoing diagnostic coronary
angiography
Progress in Interventional Cardiology - Postępy w Kardiologii Interwencyjnej2012article
Onuma Y, Girasis C, Aben JP, Sarno G, Piazza N, Lokkerbol C, Morel MA and Serruys PWA novel dedicated 3-dimensional quantitative coronary analysis methodology for bifurcation lesionsEuroIntervention2011article
Chen SL, Hu ZY, Zhang JJ, Ye F, Kan J, Xu T, Liu ZZ, Zhang YJ, Zhang JX and Chen MAcute Effects of Nicardipine and Esmolol on The Cardiac Cycle, Intracardiac Hemodynamic and Endothelial Shear Stress in Patients With Unstable Angina Pectoris and Moderate Coronary Stenosis: Results From Single Center, Randomized Study.Cardiovasc Ther.2011article
Zhang JJ, Chen SL, Hu ZY, Kan J, Xu HM, Shan SJ, Liu ZZ, Ye F, Kwan TW, Nguyen K, Nanjundappa A and Nguyen TContradictory shear stress distribution prevents restenosis after provisional stenting for bifurcation lesionsJ Interv Cardiol2010article
Hu ZY, Chen SL, Zhang JJ, Shan SJ, Liu Z, Ye F, Kan J, Xu HM, Nguyen K, Kwan T, Nguyen T and Hoang TDistribution and magnitude of shear stress after coronary bifurcation lesions stenting with the classical crush technique: a new predictor for in-stent restenosisJ Interv Cardiol2010article
Wellnhofer E, Osman J, Kertzscher U, Affeld K, Fleck E and Goubergrits LFlow simulation studies in coronary arteries - impact of side branchesAtherosclerosis2010article
Schuurbiers JCH, Lopez NG, Ligthart J, Gijsen FJH, Dijkstra J, Serruys PW, Van der Steen AF and Wentzel JJIn vivo validation of CAAS QCA-3D coronary reconstruction using fusion of angiography and intravascular ultrasound (ANGUS).Catheter Cardiovasc Interv2009article
Goubergrits L, Wellnhofer E, Kertzscher U, Affeld K, Petz C and Hege HCCoronary artery WSS profiling using a geometry reconstruction based on biplane angiographyAnn Biomed Eng2009article
Ramcharitar S, Daemen J, Patterson M, Van Geuns RJ, Boersma E, Serruys P and Van der Giessen WFirst direct in vivo comparison of two commercially available three-dimensional quantitative coronary angiography systemsCatherization and Cardiovascular Interventions2008article
Bruining N, Tanimoto S, Otsuka M, Weustink A, Ligthart J, Van Mieghem C, de Feyter P, Van Domburg R and Serruys PQuantitative multi-modality imaging analysis of a bioabsorbable poly-L-lactid acid stent design in the acute phase: a comparison between 2 and 3D-QCA, QCU and QMSCT-CAEuroIntervention2008article
Wentzel J The impact of fluid dynamics and bifurcation angles on stent design and treatment strategy--2008presentation
Serruys PW, Onuma Y and Morel MA CAAS 2D / 3D QCA bifurcation approach (EBC meeting 2008)--2008presentation
Wellnofer E, Goubergrits L, Kertzcher U and Fleck ENovel non-dimensional approach to comparison of wall shear stress distributions in coronary arteries of different groups of patientsAtherosclerosis2008article
Wentzel JJ, Schuurbiers J, Gonzalo Lopez N, Gijsen FJH, Dijkstra J, Serruys PW and Van Der Steen AFWIn vivo validation of CAAS QCA-3D coronary reconstruction using fusion of angiography and intravascular ultrasound (ANGUS)European Heart Journal2008abstract
Legutko J, Rzeszutko L, Partyka L, Wojdyla R, Tijdens F, Barycz G, Slots T, Nyssen V, Kaluza G and Dudek DAccuracy and precision of a novel 3D angiographic reconstruction and quantification software (CAAS QCA 3D) in measuring intracoronary length using marker wire in angioplasty patients.TCT20072007abstract
Legutko J, Rzeszutko L, Partyka L, Barycz G, Woidyla R, Tijdens F, Wizimirski M, Slots T, Nyssen V, Kaluza G and Dudek DNovel 3D Angiographic Reconstruction and Quantification Software (CAAS QCA 3D) in Measuring Intracoronary Length8th International Cardiology Workshop2007abstract